Title of the paper: The seven year Swift-XRT point source catalog (1SWXRT) Authors: V. D'Elia, M. Perri, S. Puccetti, M. Capalbi, P. Giommi, D. N. Burrows, S. Campana, G. Tagliaferri, G. Cusumano, P. Evans, N. Gehrels, J. Kennea, A. Moretti, J. A. Nousek, J.P. Osborne, P. Romano and G. Stratta Name of the journal, year, volume and first page: 2013, A&A, 551, 142 Key words of the paper: X-ray: general, Surveys, Catalogs. The Table contains the 1SWXRT catalog of the serendipitous sources detected in 7 years of Swift-XRT observations, acquired between 2005 and 2011 and with exposure time longer than 500 seconds. Description of the columns in Table: Column Parameter Description 1 NAME source name: prefix 1SWXRT, following the standard IAU convention 2 TARGET_NAME XRT field name 3 RA Swift-XRT Right Ascension in hms in the J2000 coordinate system 4 DEC Swift-XRT Declination in hms in the J2000 coordinate system 5 SEQUENCE Swift-XRT observation number 6 START_DATE Start time of the field observations in year-month-day h:m:s 7 END_DATE End time of the field observations in year-month-day h:m:s 8 F_RATE 0.3--10 keV count rate or 90 % upper limit in counts/sec 9 F_RATE_ERR 1 sigma 0.3--10 keV count rate error in counts/sec, in case of upper limits is set to -99 10 F_FLUX 0.5--10 keV Flux or 90 % in erg cm^-2s^-1 11 F_FLUX_ERR 1 sigma 0.5--10 keV Flux error in erg cm^-2s^-1, in case of upper limits is set to -99 12 F_PROB 0.3--10 keV detection probability 13 F_SNR 0.3--10 keV S/N 14 S_RATE 0.3--3 keV count rate or 90 % upper limit in counts/sec 15 S_RATE_ERR 1 sigma 0.3--3 keV count rate error counts/sec, in case of upper limits is set to -99 16 S_FLUX 0.5--2 keV Flux or 90 % upper limit in erg cm^-2s^-1 17 S_FLUX_ERR 1 sigma 0.5--2 keV Flux error in erg cm^-2s^-1, in case of upper limits is set to -99 18 S_PROB 0.3--13 keV detection probability 19 S_SNR 0.3--3 keV S/N 20 H_RATE 2--10 keV count rate or 90 % upper limit in counts/sec 21 H_RATE_ERR 1 sigma 2--10 keV count rate in counts/sec, in case of upper limits is set to -99 22 H_FLUX 2--10 keV Flux or 90 % upper limit in erg cm^-2s^-1 23 H_FLUX_ERR 1 sigma 2--10 keV Flux error in erg cm^-2s^-1, in case of upper limits is set to -99 24 H_PROB 2--10 keV detection probability 25 H_SNR 2--10 keV S/N 26 EXPOSURE Total on-time in sec 27 HR hardness ratio = (h_rate-s_rate)/(h_rate+s_rate) (set to 99 if soft or hard counts are missing) 28 HR_ERR 1 sigma hardness ratio error evaluated with the error propagation formula (see e.g. Bevington & Robinson 1992) 29 POS_ERR Positional error at 68 % confidence level in arcsec 30 N_H Galactic hydrogen column density in cm^-2 31 BETA Energy spectral index (set to 99 if soft or hard counts are missing) 32 BETA_ERR Energy spectral index error