Date of latest modification: Februari 16, 1998
Disclaimer: this is not a definitive statement, but just a progress report on the current situation.
Fitting Crab spectra obtained from correlated images for both wide field camera 1 and 2 (w1 and w2) gives the following results.
Only observations with Crab on axis were considered, which were deconvolved with the appropriate response matrices (wfc1_iros_dec97.rmf and wfc2_iros_dec97.rmf (available at the ftp site), respectively).
Fits were made in two ways, i.e.,
1. using nearly all channels, and
2. using only energy channels 6-8, 10-23 (3.0 - 12.5 keV for wfc1, 3.3 - 11.3 keV for wfc2) to avoid bands for which
the response matrices are not yet reliable (i.e., the lowest and highest energies and the channels near the Xe L edge(channels 9 and 10) ).
Furthermore, the WFC team of SRON, Utrecht, The Netherlands advises to add a systematic error of 2.5% in quadrature
. This of course reduces the chi square considerably, as shown in fits of the second type.
A simple powerlaw model with Wisconsin absorption was applied.
Fits made with the XSPEC package are shown with the value for the galactic absorption NH fixed to 0.33 x 10^22 cm, as was also done for the Narrow Field Instruments.
For each fit the flux between 2.0 and 10 keV is given; this value should be 2.08 x 10^-8 erg/cm^2/s (assuming a column density nh = 0.33 x 10^22, photon index 2.1 and normalisation 9.7). From the values given below, we find that at present the fluxes are underestimated by a factor of say 0.8.
This means that you should multiply the flux found with the WFC software by a factor of about 1.2.
WFC1 FITS
FIT OVER ~ ALL CHANNELS
Fit over channels 2-30 (1.6 - 22.6 keV)
Reduced chi square = 6.1
Photon index = 2.11 +/- 0.01
Normalisation = 8.09 +/- 0.06 photons/s/keV
Flux (2-10 keV) = 1.7 x 10^-8 erg/cm^2/s
FIT OVER SELECTED CHANNELS
Fit over channels 6-8,10-23 (3.0 - 4.0, 4.4 - 11.5 keV)
Reduced chi square = 0.55 (systematic error of 2.5 % added in quadrature)
Photon index = 2.09 +/- 0.02
Normalisation = 7.7 +/- 0.2 photons/s/keV
Flux (2-10 keV) = 1.7 x 10^-8 erg/cm^2/s
WFC2 FITS
FIT OVER ~ ALL CHANNELS
Fit over channels 2-30 (1.8 - 25.9 keV)
Reduced chi square = 12
Photon index = 1.85 +/- 0.01
Normalisation = 5.51 +/- 0.01 photons/s/keV
Flux (2-10 keV) = 1.7 x 10^-8 erg/cm^2/s
FIT OVER SELECTED CHANNELS
Fit over channels 6-9,11-23 (3.3 - 4.7, 5.0 - 12.2 keV)
Reduced chi square = 2.4 (systematic error of 2.5% added in quadrature)
Photon index = 1.97 +/- 0.01
Normalisation = 6.83 +/- 0.07 photons/s/keV
Flux (2-10 keV) = 1.8 x 10^-8 erg/cm^2/s
Questions and comments can be addressed to
helpdesk@sax.sdc.asi.it
Back to wfc software page